MIMS EPrints (University of Southampton) · 2005 · 16 citations · 9 references
EngineeringElectrical EngineeringBiomedical ImagingDiagnostic ImagingDigital Imaging3D Imaging3D ReconstructionImage ReconstructionImagingThree-dimensional Reconstruction3D MeasurementElectrical ImpedanceElectrical Impedance TomographyImpedance ReconstructionMeasurementReconstruction AlgorithmsThree-dimensional Image ReconstructionThree-dimensional Tomography
The present status of electrical impedance tomography (EIT) is such that many successful laboratory\nbased studies and pilot plant demonstrators are generating interest in developing the technology.\nHowever, while the EIT problem is inherently 3D, many studies make 2D assumptions in order to\nsimplify the problem. Proportionately less work has been carried out on the true 3D EIT problem,\noutside of the mathematical development of the problem. This paper aims to provide a comparison of\nthe performance of 3D EIT image reconstruction algorithms applied to real data, and assess whether\nthe extra effort and complexity involved in 3D EIT is worthwhile. Measurement data are taken from a\npilot-scale mixing vessel. The performance of five common EIT reconstruction algorithms is compared\nand the best performing algorithm for this arrangement is identified. This work is part of the ongoing\nefforts at Manchester to pursue the true 3D EIT problem under the EIDORS-3D framework.
9
Nick Polydorides, William Lionheart · Measurement Science and Technology · 2002 · 454 citations
Engineering, Biomedical Engineering, Electrical Engineering +15