PLoS ONE · 2015 · 111 citations · 32 references
MedicineRadiologyDiagnostic ImagingDiagnostic RadiologyThoracic RadiologyChest RadiographyChest RadiologyComputed TomographyMedical ImagingPulmonary Nodule EvaluationRadiographic ImagingHigh-resolution ImagingHigh-resolution TomographyImage Noise AssessmentImage Noise EstimationImage Noise ReductionImage Quality BenchmarkingInstitutional Review Board ApprovalRadiographic Image Quality
PURPOSE: The image noise and image quality of a prototype ultra-high-resolution computed tomography (U-HRCT) scanner was evaluated and compared with those of conventional high-resolution CT (C-HRCT) scanners. MATERIALS AND METHODS: This study was approved by the institutional review board. A U-HRCT scanner prototype with 0.25 mm x 4 rows and operating at 120 mAs was used. The C-HRCT images were obtained using a 0.5 mm x 16 or 0.5 mm x 64 detector-row CT scanner operating at 150 mAs. Images from both scanners were reconstructed at 0.1-mm intervals; the slice thickness was 0.25 mm for the U-HRCT scanner and 0.5 mm for the C-HRCT scanners. For both scanners, the display field of view was 80 mm. The image noise of each scanner was evaluated using a phantom. U-HRCT and C-HRCT images of 53 images selected from 37 lung nodules were then observed and graded using a 5-point score by 10 board-certified thoracic radiologists. The images were presented to the observers randomly and in a blinded manner. RESULTS: The image noise for U-HRCT (100.87 ± 0.51 Hounsfield units [HU]) was greater than that for C-HRCT (40.41 ± 0.52 HU; P < .0001). The image quality of U-HRCT was graded as superior to that of C-HRCT (P < .0001) for all of the following parameters that were examined: margins of subsolid and solid nodules, edges of solid components and pulmonary vessels in subsolid nodules, air bronchograms, pleural indentations, margins of pulmonary vessels, edges of bronchi, and interlobar fissures. CONCLUSION: Despite a larger image noise, the prototype U-HRCT scanner had a significantly better image quality than the C-HRCT scanners.
32
Fleischner Society: Glossary of Terms for Thoracic Imaging
David M. Hansell, Alexander A. Bankier, Heber MacMahon et al. · Radiology · 2008 · 4.3K citations
Claudia I. Henschke, David F. Yankelevitz, Rosna Mirtcheva et al. · American Journal of Roentgenology · 2002 · 911 citations
Solitary pulmonary nodule: high-resolution CT and radiologic-pathologic correlation.
Charles Zwirewich, Sverre Vedal, Roberta R. Miller et al. · Radiology · 1991 · 532 citations
Focal Ground-Glass Opacity Detected by Low-Dose Helical CT
Masao Nakata, Hideyuki Saeki, Ichiro Takata et al. · CHEST Journal · 2002 · 276 citations