Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign) · 2000 · 11 citations · 29 references
Open access
EngineeringMaterials ScienceMechanical EngineeringFluid DynamicsMicrofabricationTransport PhenomenaMicrofluidic Device FabricationMicrofluidic DevicesMicrofluidic SystemsMicrofluidic TransportMicrofluidicsVoid FractionMicrochannel DesignMicrochannel FlowPressure DropVoid Fraction DistributionVoid Fraction Profiles
An experimental investigation of pressure drop and void fraction in aluminum \nmicrochannel tubes was conducted for a variety of flow conditions. Primary fluids of \ninterest are refrigerants, R134a and R41OA. The microchannel tubes are square port \ngeometries with hydraulic diameters of 0.91 and 1.35 mm for test section lengths of 61 \nand 107cm (24" and 42"). The test matrix encompasses the entire quality range from 0-1, \nmass fluxes from 75 kglm2s to 350 kglm2s, and 3 temperatures from 10 to 35 DC. Test \nsections are adiabatic and in a horizontal orientation. \nSingle-phase and two-phase pressure drop data were taken. No "small-tube" \neffects due to the hydraulic diameter were found for single-phase frictional pressure drop. \nTwo-phase pressure drop was found to be mass flux dependent. A change in pressure \ndrop behavior as mass flow rates increased beyond a set value is caused by a two-phase \nflow regime transition. Available pressure drop correlations tend to consistently \noverpredict the experimental pressure drop. \nA new microchannel testing facility was constructed at the University of Illinois at \nUrbana-Champaign. Details on system design, components, and operation are given.
29