2015 · 10 citations · 10 references
EngineeringElectrical EngineeringAgricultural ElectrificationPower ElectronicsPowertrain EngineeringElectric DrivesElectric Motor Drive SystemsElectric Motor DrivesElectric MotorsInduction MachinesMultilevel ConvertersBearing FailureInduction Motor DrivesInvertersMotor Drive SystemsMultilevel InvertersParasitic CouplingPulse Width Modulation TechniquesVoltage Source Inverters
A Pulse Width Modulation (PWM) Voltage Source Inverter (VSI) fed induction motor drive has superior dynamic characteristics than sine wave driven induction motor. But it has a problem with induced bearing voltage and high frequency bearing current that flows through bearings due to parasitic capacitive coupling that results in premature bearing failure. In many industrial applications the PWM inverters and motors must be at separate locations thus requiring long motor cable, which contributes over voltage and higher common mode voltage at the motor terminal due to voltage reflection phenomenon. Higher common mode voltage results in higher induced shaft voltage and bearing currents. This paper presents simulation and analysis of influence of motor cable length on the magnitude of common mode voltage, bearing voltage and bearing current in two level and three level diode clamped multilevel inverter fed induction motor drive. The dv/dt of common mode voltage and bearing voltage also presented. Simulation is carried out using MATLAB/simulink.
10
Effect of PWM inverters on AC motor bearing currents and shaft voltages
J. Erdman, R.J. Kerkman, D. Schlegel et al. · 1995 · 127 citations
Shaft currents in electric machines
Alger, Samson · Journal of the A.I.E.E. · 1924 · 74 citations