ACI Concrete International · 1991 · 29 citations · 0 references
EngineeringCivil EngineeringMarine EngineeringCoastal EngineeringHydraulic EngineeringHydraulicsCavitationDam HydraulicsHydraulic ModelingHydraulic StructuresSpillway DesignSpillway OperationsAerated SpillwaysCavitation DamageCavitation In SpillwaysCavitation ModelingDam DesignSpillway HydraulicsSpillwaysStepped Spillway Design
Cavitation at Hoover Dam, Nevada is described, and predicting cavitation damage is discussed, as well as aeration device, and surface tolerance specifications. Stepped spillways are described. Research on stepped spillways suggests that they may be viable alternatives to cavitation-prone smooth spillways. It is recommended that surface tolerances alone should not be relied to upon to prevent cavitation damage to a spillway structure. Consideration must be given to the cavitation potential of a structure early in the design process. Preliminary design must be analyzed using current spillway-flow computer models which compute flow-cavitation indices as a function of stationing and discharge. Design alternatives, including stepped spillways, should be considered when the cavitation indices are less than 0.2.