Designing Spillways to Prevent Cavitation Damage

Kathleen H. Frizell, Brent Mefford

ACI Concrete International · 1991 · 29 citations · 0 references

Concepts

Abstract

Cavitation at Hoover Dam, Nevada is described, and predicting cavitation damage is discussed, as well as aeration device, and surface tolerance specifications. Stepped spillways are described. Research on stepped spillways suggests that they may be viable alternatives to cavitation-prone smooth spillways. It is recommended that surface tolerances alone should not be relied to upon to prevent cavitation damage to a spillway structure. Consideration must be given to the cavitation potential of a structure early in the design process. Preliminary design must be analyzed using current spillway-flow computer models which compute flow-cavitation indices as a function of stationing and discharge. Design alternatives, including stepped spillways, should be considered when the cavitation indices are less than 0.2.