PubMed · 1957 · 42 citations · 0 references
PharmacyToxicologyAir PollutionPulmonologyToxicodynamicsAerosol ScienceLung DepositionParticulate MatterPulmonary PhysiologyPulmonary ToxicologyRespiratory ToxicologyAerosol Deposition In AirwaysAerosol Deposition MechanismsAerosol Particle DepositionBrownian Motion AnalysisBrownian Motion EffectsInhalable Particle DepositionInhalation Aerosol DynamicsRespiratory Deposition
Three volunteers were exposed via mouth inhalation to triphenyl phosphate (non-hygroscopic). Particle sizes tested ranged from 0.14 to 3.2 ..mu..m (6 homogenous steps). Deposition curves show minimum retention of 0.4 ..mu..m particle size. Brownian motion (random impact with gas) varies by d/sup -//sup 1/2; settling effect and impact effect vary by d/sup 2/ so minimum deposition is where these three processes counteract each other. Slower, deeper breathing resulted in greater deposition; differences were greater with larger particles, because settling and impaction vary with first power of time and Brownian varies with square root of time. Pneumoconiosis-producing dusts act on deep pulmonary tissues whereas major cancer producers act on the bronchi.