Aerosol deposition in the human respiratory tract. I. Experimental procedures and total deposition.

Bernard Altshuler, L. Yarmus, Palmes Ed, Norton Nelson

PubMed · 1957 · 42 citations · 0 references

Concepts

Abstract

Three volunteers were exposed via mouth inhalation to triphenyl phosphate (non-hygroscopic). Particle sizes tested ranged from 0.14 to 3.2 ..mu..m (6 homogenous steps). Deposition curves show minimum retention of 0.4 ..mu..m particle size. Brownian motion (random impact with gas) varies by d/sup -//sup 1/2; settling effect and impact effect vary by d/sup 2/ so minimum deposition is where these three processes counteract each other. Slower, deeper breathing resulted in greater deposition; differences were greater with larger particles, because settling and impaction vary with first power of time and Brownian varies with square root of time. Pneumoconiosis-producing dusts act on deep pulmonary tissues whereas major cancer producers act on the bronchi.