PLoS ONE · 2015 · 114 citations · 24 references
MedicineOrthopaedic SurgeryOrthopedic SurgeryMovement AnalysisOrthopedicsPhysical TherapyJoint Motion AnalysisShoulder AnatomyShoulder BiomechanicsShoulder DisordersCohen's Kappa InterpretationDiagnostic Cutoff ValuesIntraclass CorrelationKappa CoefficientKappa StatisticShoulder ImagingShoulder Joint AssessmentShoulder Kinematics
Range of motion (ROM) measurements are essential for the evaluation for and diagnosis of adhesive capsulitis of the shoulder (AC). However, taking these measurements using a goniometer is inconvenient and sometimes unreliable. The Kinect (Microsoft, Seattle, WA, USA) is gaining attention as a new motion detecting device that is nonintrusive and easy to implement. This study aimed to apply Kinect to measure shoulder ROM in AC; we evaluated its validity by calculating the agreement of the measurements obtained using Kinect with those obtained using goniometer and assessed its utility for the diagnosis of AC. Both shoulders of 15 healthy volunteers and affected shoulders of 12 patients with AC were included in the study. The passive and active ROM of each were measured with a goniometer for flexion, abduction, and external rotation. Their active shoulder motions for each direction were again captured using Kinect and the ROM values were calculated. The agreement between the two measurements was tested with the intraclass correlation coefficient (ICC). Diagnostic performance using the Kinect ROM was evaluated with Cohen's kappa value. The cutoff values of the limited ROM were determined in the following ways: the same as passive ROM values, reflecting the mean difference, and based on receiver operating characteristic curves. The ICC for flexion/abduction/external rotation between goniometric passive ROM and the Kinect ROM were 0.906/0.942/0.911, while those between active ROMs and the Kinect ROMs were 0.864/0.932/0.925. Cohen's kappa values were 0.88, 0.88, and 1.0 with the cutoff values in the order above. Measurements of the shoulder ROM using Kinect show excellent agreement with those taken using a goniometer. These results indicate that the Kinect can be used to measure shoulder ROM and to diagnose AC as an alternative to goniometer.
24
Clinical Measurement of Range of Motion
Richard L. Gajdosik, Richard W. Bohannon · Physical Therapy · 1987 · 892 citations
Validity of the Microsoft Kinect for assessment of postural control
Ross A. Clark, Yong‐Hao Pua, Karine Fortin et al. · Gait & Posture · 2012 · 687 citations
Goniometric Reliability in a Clinical Setting
Jules M Rothstein, Peter Miller, Richard F. Roettger · Physical Therapy · 1983 · 552 citations
Goniometric Reliability in a Clinical Setting
Daniel L. Riddle, Jules M Rothstein, Robert L. Lamb · Physical Therapy · 1987 · 387 citations
Ron L. Diercks, Martin Stevens · Journal of Shoulder and Elbow Surgery · 2004 · 315 citations