Applied and Environmental Microbiology · 1981 · 25 citations · 12 references
Life SciencesBiochemistryMicrobiologyEnzymologyFermentation ScienceMicrobial PhysiologyBacterial FermentationBioanalytical ChemistryEnzyme CharacterizationEnzyme ImmobilizationEnzyme KineticsMicrobial FermentationCalorimetric DetectorsMicrobial Kinetics
Immobilized penicillinase was applied in an enzyme thermistor for calorimetric analysis of samples containing penicillin G. Standard solutions as well as extracts from fermentation broth were analyzed. The enzyme was applied bound either to porous glass or, when dealing with crude preparations, to the inner surface of nylon tubing. In the fermentation system studied, high concentrations of penicillin were present, thus allowing dilution to reduce the influence of the composition of the medium on the analysis. The useful linear concentration range was from 0.1 to 100 mM. The coefficient of correlation between analytical results obtained with the present method and those from conventional assays was 0.997.
12
Klaus Mosbach, Bengt Danielsson, Anders Borgerud et al. · Biochimica et Biophysica Acta (BBA) - Enzymology · 1975 · 68 citations