Assessment of variables affecting the accuracy of extravascular lung water (EVLW) by single versus double indicator dilution techniques in ARDS patients

Elena Maggioni, Francesco Sala, A Manfio, E. Saccavino, Barbara Cortinovis, Giacomo Bellani, Nicolò Patroniti

Critical Care · 2003 · 250 citations · 72 references

DOIFull text

Open access

Concepts

Abstract

Estimation of extravascular lung water (EVLW) by the single indicator dilution technique (SDT) implemented in the PICCO monitoring system relies on a relationship between intrathoracic blood volume (ITBV) and global end diastolic volume (GEDV), which has been derived from a large population of mixed critically ill patients using the double indicator dilution technique (thermal and indocyanine green dyes, DDT): ITBV sdt = 1.25 × GEDV [ 1 ]. Since the difference between ITBV and GEDV corresponds to pulmonary blood volume (PBV), we can write: PBV sdt = 0.25 × GEDV. Any factor influencing this relationship can affect SDT accuracy. The aims of our study were: 1) to compare SDT versus DDT for EVLW measurements in ARDS patients; and 2) to explore factors influencing the PBV and GEDV relationship, and affecting SDT accuracy.

References

72