Journal of Clinical Microbiology · 1989 · 106 citations · 17 references
Veterinary MedicineInfectious DiseasesMicrobiologyBacteriologyMedical MicrobiologySepsisBacterial InfectionsBacterial PathogenesisSepsis ManagementSepsis PathophysiologySeptic ShockTransfusion-transmitted InfectionsEndotoxin ContaminationPathogen Growth During StoragePathogen Survival During StorageStorage Effects On Toxin FormationTransfusion In SepsisTransfusion-associated SepsisTransfusion-transmitted Bacterial Infections
Since 1987, the Centers for Disease Control investigated six cases of transfusion-associated sepsis. All six patients developed septic shock after receiving units of packed erythrocytes (PRBCs) contaminated with Yersinia enterocolitica (five patients) and Enterobacter agglomerans (one patient); three of the blood recipients died. We studied the growth and endotoxin production of Y. enterocolitica and E. agglomerans in units of PRBCs stored at 4 degrees C for 60 days. When PRBCs were inoculated with 0.1 to 1.0 CFU of these organisms per ml, both Y. enterocolitica and E. agglomerans entered log-phase growth 2 to 3 weeks after inoculation; generation times were 15 and 22 h, respectively. Endotoxin was first detected at 3 weeks following inoculation, and the concentration paralleled the log phase of growth of the strains tested. These data show that prolonged storage of PRBCs at 4 degrees C provides conditions that allow these two organisms to grow and subsequently produce high concentrations of endotoxin.
17
Mark Stenhouse, Lisa Milner · Transfusion · 1982 · 82 citations
Pseudomonas fluorescens bacteremia from blood transfusion
Rima Khabbaz, Paul M. Arnow, Anita K. Highsmith et al. · The American Journal of Medicine · 1984 · 49 citations