Investigative Ophthalmology & Visual Science · 2015 · 43 citations · 24 references
Health ProfessionsOphthalmologyVeterinary OphthalmologyBiomedical OpticsBiophotonicsOcular ImagingCorneal AnatomyCorneal ImagingCorneal PhysiologyOcular BioavailabilityRabbit OphthalmologyCollagen-based Corneal MaterialsCorneal AbsorptionCorneal Epithelial DamageCorneal Epithelial HealingCorneal Epithelial ResponseDrug Absorption Across The CorneaEx Vivo Corneal ModelsRiboflavin Absorption
PURPOSE: To measure depth-specific riboflavin concentrations in corneal stroma using two-photon fluorescence microscopy and compare commercially available transepithelial corneal collagen cross-linking (CXL) protocols. METHODS: Transepithelial CXL riboflavin preparations--MedioCross TE, Ribocross TE, Paracel plus VibeX Xtra, and iontophoresis with Ricrolin+--were applied to the corneal surface of fresh postmortem rabbit eyes in accordance with manufacturers' recommendations for clinical use. Riboflavin 0.1% (VibeX Rapid) was applied after corneal epithelial debridement as a positive control. After riboflavin application, eyes were snap frozen in liquid nitrogen. Corneal cross sections 35-μm thick were cut on a cryostat, mounted on a slide, and imaged by two-photon fluorescence microscopy. Mean (SD) concentrations were calculated from five globes tested for each protocol. RESULTS: Peak riboflavin concentration of 0.09% (± 0.01) was observed within the most superficial stroma (stromal depth 0-10 μm) in positive controls (epithelium-off). At the same depth, peak stromal riboflavin concentrations for MedioCross TE, Ricrolin+, Paracel/Xtra, and Ribocross TE were 0.054% (± 0.01), 0.031% (0.003), 0.021% (± 0.001), and 0.015% (± 0.004), respectively. At a depth of 300 μm (within the demarcation zone commonly seen after corneal cross-linking), the stromal concentration in epithelium-off positive controls was 0.075% (± 0.006), while at the same depth MedioCross TE and Ricrolin+ achieved 0.018% (± 0.006) and 0.016% (0.002), respectively. None of the remaining transepithelial protocols achieved concentrations above 0.005% at this same 300-μm depth. Overall, MedioCross TE was the best-performing transepithelial formulation. CONCLUSIONS: Corneal epithelium is a significant barrier to riboflavin absorption into the stroma. Existing commercial transepithelial CXL protocols achieve relatively low riboflavin concentrations in the anterior corneal stroma when compared to gold standard epithelium-off absorption. Reduced stromal riboflavin concentration may compromise the efficacy of riboflavin/ultraviolet corneal CXL.
24
A Randomized, Controlled Trial of Corneal Collagen Cross-Linking in Progressive Keratoconus
Christine Wittig-Silva, Elsie Chan, Amirul Islam et al. · Ophthalmology · 2014 · 707 citations · Full text
Medicine, Ophthalmology, Surgery +13