Loss Model for Off-Design Performance Analysis of Radial Turbines with Pivoting-Vane, Variable-Area Stators

Peter L. Meitner, A. J. Glassman

SAE technical papers on CD-ROM/SAE technical paper series · 1980 · 18 citations · 5 references

DOIFull text

Open access

Concepts

Abstract

<div class="htmlview paragraph">An off-design performance loss model is developed for variable-area (pivoted vane) radial turbines. The variation in stator loss with stator area is determined by a viscous loss model while the variation in rotor loss due to stator area variation (for no stator end-clearance gap) is determined through analytical matching of experimental data. An incidence loss model is also based on matching of the experimental data. A stator vane end-clearance leakage model is developed and sample calculations are made to show the predicted effects of stator vane end-clearance leakage on performance.</div>

References

5