Concepedia

Publication | Open Access

The Research Diagnostic Criteria for Temporomandibular Disorders. V: methods used to establish and validate revised Axis I diagnostic algorithms.

235

Citations

44

References

2010

Year

TLDR

To derive reliable and valid revised Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms for clinical TMD diagnoses. The authors used a multisite RDC/TMD Validation Project dataset of 614 TMD cases and 91 controls, deriving algorithms and evaluating them against expert consensus reference standards with sensitivity ≥0.70 and specificity ≥0.95, and testing reliability in 27 participants. The revised algorithms achieved target sensitivity and specificity for myofascial pain (0.82–0.93/0.97–0.99) and joint pain (0.92/0.96), but fell short for certain disc displacement and osteoarthritis diagnoses, with kappa ≥0.63 indicating acceptable reliability.

Abstract

To derive reliable and valid revised Research Diagnostic Criteria for Temporomandibular Disorders (RDC/TMD) Axis I diagnostic algorithms for clinical TMD diagnoses.The multisite RDC/TMD Validation Project's dataset (614 TMD community and clinic cases, and 91 controls) was used to derive revised algorithms for Axis I TMD diagnoses. Validity of diagnostic algorithms was assessed relative to reference standards, the latter based on consensus diagnoses rendered by two TMD experts using criterion examination data, including temporomandibular joint imaging. Cutoff points for target validity were sensitivity > or = 0.70 and specificity > or = 0.95. Reliability of revised algorithms was assessed in 27 study participants.Revised algorithm sensitivity and specificity exceeded the target levels for myofascial pain (0.82, 0.99, respectively) and myofascial pain with limited opening (0.93, 0.97). Combining diagnoses for any myofascial pain showed sensitivity of 0.91 and specificity of 1.00. For joint pain, target sensitivity and specificity were observed (0.92, 0.96) when arthralgia and osteoarthritis were combined as "any joint pain." Disc displacement without reduction with limited opening demonstrated target sensitivity and specificity (0.80, 0.97). For the other disc displacement diagnoses, osteoarthritis and osteoarthrosis, sensitivity was below target (0.35 to 0.53), and specificity ranged from 0.80 to meeting target. Kappa for revised algorithm diagnostic reliability was > or =0.63.Revised RDC/TMD Axis I TMD diagnostic algorithms are recommended for myofascial pain and joint pain as reliable and valid. However, revised clinical criteria alone, without recourse to imaging, are inadequate for valid diagnosis of two of the three disc displacements as well as osteoarthritis and osteoarthrosis.

References

YearCitations

Page 1