Measurement Science and Technology · 2001 · 25 citations · 1 references
EngineeringNuclear EngineeringNuclear InstrumentationRadiation DosimetrySensorsRadiation InstrumentationRadiation Monitoring SystemsReactor InstrumentationTemperature MeasurementTemperature SensorsThermal SensorsFast Reactor ApplicationsLoss Distribution EstimationProtection Of Nuclear FacilitiesRadiation-induced Error MitigationTemperature CompensationTemperature Monitoring TechnologiesThermocouple-based SensingTotal Dose
In order to apply a Raman distributed temperature sensor (RDTS) to the monitoring of nuclear facilities, some correction techniques for radiation-induced errors were developed and investigated. One is a simple correction technique with two thermocouples, when uniform radiation-induced loss distribution can be assumed. The other is a special technique with a loop-type arrangement. In this technique, even when the loss distribution is not uniform, radiation-induced errors can be cancelled. To demonstrate these techniques, RDTS has been installed at the experimental fast reactor JOYO. During continuous measurements with a total dose of more than 7.7×103 C kg-1 (3.0×107 R), the radiation-induced error showed a tendency to saturate and the feasibility of the correction techniques was demonstrated. These results show that RDTS could be useful as a temperature distribution monitor in nuclear plants.