Journal of Separation Science · 2015 · 24 citations · 18 references
Natural SciencesChemical EngineeringChemistryAnalytical ChemistryNuclear ChemistrySeparation ProcessesMicrofluidicsSolvent ExtractionConcentrationContact Time EffectsExtraction KineticsFirst-order KineticsLiquid Scintillation CountingPseudo-first-order KineticsRate Constant DeterminationSolution Contact Time
Extraction of Pu(IV) with tri-n-butylphosphate is performed using a glass chip microchannel to evaluate the extraction rate. Two-phase flow forms in the microchannel by introducing a solution of Pu(IV) and tri-n-butylphosphate with flow rates above 5 μL/min. The Pu(IV) extraction reaction proceeds at the interface between the two phases. To evaluate the extraction rate, the contact time between the two phases is varied from 0.48 to 4.8 s by changing the confluent length of the microchannel and the flow rate. The Pu concentration of each phase collected from the microchannel is measured with an alpha liquid scintillation counter, and the contact time dependence of Pu(IV) extraction is obtained. An extraction model based on diffusion in the microchannel and the reaction at the interface is proposed and applied to determine the extraction rate. The extraction process is assumed to follow pseudo-first-order kinetics, and the extraction rate constant of Pu(IV) is determined to be 1.5 × 10(-2) cm/s. The investigation demonstrates that a microfluidic device can be a new tool to determine Pu(IV) extraction rates.
18
Kevin P. Nichols, Rebecca R. Pompano, Liang Li et al. · Journal of the American Chemical Society · 2011 · 123 citations
Hiroyasu Hotokezaka, Manabu Tokeshi, Masayuki Harada et al. · Progress in Nuclear Energy · 2005 · 87 citations