PubMed · 1973 · 16 citations · 0 references
MedicineSurgeryBowel ManagementLaparoscopic UrologySurgical InstrumentationGastrointestinal PerforationLaparoscopic SurgeryMinimally Invasive SurgeryCauterization TreatmentManipulationProcedure ComplicationsSmall Bowel PerforationSmall Bowel SurgerySurgical Bowel Resection
2 cases of perforation of the small intestine following laparoscopic tubal cauterization and the necessity of perfectly working equipment to prevent such complications are described. The Bovie unit must be calibrated the cautery tong sheath should have no nicks or scratches. The patient should be in steep Trendelenberg position. The abdomen should be adequately distended and refilled frequently to compensate for lost gas. Good manipulation of the cervix and catheterization of the bladder are important. Since these perforations probably occurred from sparking the authors recommend disconnecting the cautery except when in use. If perforation is suspected bowel resection is needed without delay.