Optometry and Vision Science · 2005 · 79 citations · 7 references
MedicineOphthalmologyPediatricsClinical Vision SciencePediatric OphthalmologyPediatric OptometryCorneal DisordersCorneal ImagingCorneal TopographyPediatric Corneal DisordersPediatric Vision ScreeningCentral Corneal Thickness MeasurementChildhood Vision DisordersCorneal Thickness AssessmentInterocular AsymmetryLaser Vision Correction ScreeningPearson Correlation CoefficientPosterior Corneal Elevation AnalysisSimulated Keratometry
PURPOSE: To compare the sensitivity of 11 preschool vision screening tests administered by licensed eye care professionals for the detection of the 4 Vision in Preschoolers (VIP)-targeted vision disorders when specificity is 94%. METHODS: This study consisted of a sample (n = 2588) of 3- to 5-year-old children enrolled in Head Start programs, 57% of whom had failed an initial Head Start vision screening. Screening results from 11 tests were compared with results from a standardized comprehensive eye examination that was used to classify children with respect to the four VIP-targeted vision disorders: amblyopia, strabismus, significant refractive error, and unexplained reduced visual acuity (VA). With overall specificity set to 94%, we calculated the sensitivity for the detection of each targeted vision disorder. RESULTS: With the overall specificity set to 94%, the most accurate tests for detection of amblyopia were noncycloplegic retinoscopy (NCR) (88% sensitivity), the SureSight Vision Screener (80%), and the Retinomax Autorefractor (78%). For detection of strabismus, the most accurate tests were the MTI Photoscreener (65%), the cover-uncover test (60%), the Stereo Smile II stereoacuity test (58%), the SureSight Vision Screener (54%), and the Retinomax Autorefractor (54% in year 1, 53% in year 2). The most accurate tests for detection of significant refractive error were NCR (74%), the Retinomax Autorefractor (66%), the SureSight Vision Screener (63%), and the Lea Symbols VA test (58%). For detection of reduced VA, the most accurate tests were the Lea Symbols Distance VA test (48%), the Retinomax Autorefractor (39%), and NCR (38%). CONCLUSIONS: Similar to the previously reported results at 90% specificity, the screening tests vary widely in sensitivity with specificity set at 94%. The rankings of the sensitivities for detection of the 4 VIP-targeted vision disorders are similar to those with specificity set to 90%.
7
Sean P. Donahue, Robert W. Arnold, James B. Ruben · Journal of American Association for Pediatric Ophthalmology and Strabismus · 2003 · 222 citations
Medicine, Ophthalmology, Pediatrics +14