MedicineNephrologySurgeryDialysisHemodialysisRenal Replacement TherapyChronic HemodialysisDialysis AccessDialysis Access InterventionsDialysis Vascular AccessVascular AccessVascular Access CareActuarial Survival AnalysisLong-term Graft PatencyVascular Access DevicesVascular Access DysfunctionVascular Access EvaluationVascular Access PatencyVascular Access Thrombosis
A total of 21 patients with vascular access problems received 22 PTFE loop grafts in the thigh as vascular access for haemodialysis. Eighteen of 22 grafts supported haemodialysis during the patients' lifetime. Actuarial patient survival was 50% at 2 years with a cumulative graft patency in the survivors of 80.5%. Although early thrombosis has been a problem, no graft has been lost from infection. We feel that these results are encouraging enough to recommend the use of PTFE grafts in the thigh of patients with vascular access problems.
6
Saphenous-Vein Arteriovenous Fistula in Regular Dialysis Treatment
James R. May, David J. Tiller, James R. Johnson et al. · New England Journal of Medicine · 1969 · 158 citations
Medicine, Nephrology, Surgery +7
Experience with arterial substitutes in the construction of vascular access for hemodialysis.
M Haimov, L Burrows, H Schanzer et al. · PubMed · 1980 · 56 citations