Abstract

In order to study critically some physical char- acteristics and biological properties of insulin we needed an accurate measurement of the molarity of insulin solutions. Herskovits (1965) has measured the concentration ofinsulin by nitrogen analysis and published a value for the molar extinction coefficient of 5-96 x 103 at 277nm. This contrasts with the value of 5*22 x 103 obtained by Praissman & Rupley (1968) from dry-weight determinations corrected for counterion content. It occurred to us that this considerable difference could arise if the wrong value for the nitrogen content of insulin was assumed. The amide nitrogen atoms of insulin are known to be labile In an extreme case insulin could lose 6 amide nitrogen atoms/mol., thus decreasing its nitrogen content from 65 to 59 atoms/mol. (Sanger, 1960). Another potential source of error is the small but measurable amount of proinsulin that commercial preparations of insulin are known to contain (Schmidt & Arens, 1968).

References

6