The International Journal of Artificial Organs · 2004 · 12 citations · 16 references
MedicineCardiologySurgeryCardiothoracic SurgeryHemodynamic ManagementPediatric CardiologyCardiovascular AnatomyCongenital Heart SurgeryHemodynamicsHemodynamics ModelingPediatric Cardiac SurgeryThoracic SurgeryBlood FlowBlood Flow SimulationBlood Flow VisualizationFlow Pattern AnalysisPulmonary Blood Flow ModelingPulmonary Blood Flow RegulationPulmonary HemodynamicsSystemic-to-pulmonary Shunt Surgery
UNLABELLED: The aim of this work was the application of computer and physical in vitro simulation methods for estimating surgery procedure hemodynamics. The modified Blalock-Taussig (mB-T) palliative surgical procedure is performed to increase the pulmonary blood flow in children with congenital heart defects. Such a systemic-to-pulmonary shunt yields substantial modification in the blood flow within the large blood vessels. The objective of the present study was to investigate basic characteristics of the flow, flow pattern and pressure-flow efficiency, before and after opening of the mB-T graft. METHODS: The model was based on the vessel geometry obtained from the Visible Human Project and included the arch of aorta, the three arteries branching from the arch, the pulmonary trunck, and the left and right pulmonary arteries. The graft was added between the left subclavian artery and the left pulmonary artery. The glass model of the vessels was produced and investigated in a physical model of the cardiovascular system with an artificial ventricular device as the blood pump. Flow rate and hydrostatic pressure were measured at the inlet to and outlets from the glass model and in a few points within the system. Laser flow visualization was also performed. Computer simulations were done using the boundary conditions from the physical model. RESULTS: The opening of the mB-T graft changed flow distribution in all branches (including inflow). A complex flow pattern with large eddies and channelling of the flow in the vicinity of the graft and within it was observed in flow visualization and in computer simulations. Because of that complexity the local measurements of hydrostatic pressure at the vessel wall could not predict the average flow rate. The reversed flow in the graft was observed during the systole. CONCLUSIONS: The complex flow pattern developed in the physical model of the mB-T graft. The channelling of the flow and the formation of large eddies may yield high shear stress and modify blood properties. The rigid wall model can describe only some flow characteristics observed in vivo. Computer simulation is a very fast and accurate method which permits earlier qualification of cardiac surgeons on how to change cardiac vascular blood flow after operations.
16
Marc R. de Leval, Gabriele Dubini, Francesco Migliavacca et al. · Journal of Thoracic and Cardiovascular Surgery · 1996 · 264 citations · Full text
Modified Blalock-Taussig shunt
Marc R. de Leval, Roxane McKay, Michael Jones et al. · Journal of Thoracic and Cardiovascular Surgery · 1981 · 200 citations
Shiva Sharma, Sean Goudy, Peter G. Walker et al. · Journal of the American College of Cardiology · 1996 · 132 citations
Medicine, Cardiology, Surgery +11