Lung release of HIPDM: a new index of lung dysfunction for clinical and experimental studies.

Massimo Pistolesi, Massimo Miniati, L. Ghelarducci, N Mazzuca, C. Giuntini, E. Taccini, Giacomo Renzoni, N. Pellegrini, Maria Carla Gilardi, P. Gerundini

Unicam Scientific Publications (University of Camerino) · 1985 · 11 citations · 0 references

Concepts

Abstract

Lung uptake,metabolism and release of amines has been\n experimentally documented. We studied in rabbit and man the lung kinetics of radioiodinated N-N-N'-trimethyl-N--(2-hydroxy-3-methyl-5-iodobenzyl) -1,3-propanediamine (HIPDM) in rabbits,after i.v.injection, 95% of HIPDM is kept within the lungs and is then released with a mean time (E) of several hours as assessed both in vivo, by gamma camera external counting (n=5,t=7.0hrs), and in vitro by measuring activity in lung homogenates at various times after injection (n=56,.t=7.6 hrs). In 10 healthy non smoking subjects t was 6.4+/-1 hrs, whereas it was 12.1±2hrs in 10 asymptomatic smokers with normal pulmonary function tests.\nPreliminary clinical studies showed that HIPDM lung release is delayed in non smoking patients with primary pulmonary\nhypertension(n=4,E=U.5t2hrs) and to a greater extent L\nadult respiratory distress syndrome (n-4;E-25 8+5 hrs)\nwhereas it was not significantly affected in cardiogenic\npulmonary edema (n=4; t=8. 8±2 hrs).\nHence both smoke exposure and injury to the lung microcir-\nculation may impair HIPDM lung kinetics. HIPDM external\ncounting may therefore provide a new index of lung dysfunc-\ntion in man. Rabbit can be used as a model to evaluate HIPDM\nlung kinetAcs in experimentally induced lung injury.