Laparoscopic hernia repair and bladder injury.

Kathie M. Dalessandri, Sunil Bhoyrul, Sean J. Mulvihill

PubMed · 2001 · 26 citations · 13 references

Full text

Open access

Concepts

Abstract

BACKGROUND: Bladder injury is a complication of laparoscopic surgery with a reported incidence in the general surgery literature of 0.5% and in the gynecology literature of 2%. We describe how to recognize and treat the injury and how to avoid the problem. CASE REPORTS: We report two cases of bladder injury repaired with a General Surgical Interventions (GSI) trocar and a balloon device used for laparoscopic extraperitoneal inguinal hernia repair. One patient had a prior appendectomy; the other had a prior midline incision from a suprapubic prostatectomy. We repaired the bladder injury, and the patients made a good recovery. CONCLUSION: When using the obturator and balloon device, it is important to stay anterior to the preperitoneal space and bladder. Prior lower abdominal surgery can be considered a relative contraindication to extraperitoneal laparoscopic hernia repair. Signs of gas in the Foley bag or hematuria should alert the surgeon to a bladder injury. A one- or two-layer repair of the bladder injury can be performed either laparoscopically or openly and is recommended for a visible injury. Mesh repair of the hernia can be completed provided no evidence exists of urinary tract infection. A Foley catheter is placed until healing occurs.

References

13