Fusion Science & Technology · 2015 · 10 citations · 7 references
EngineeringMaterials EngineeringMaterials ScienceMetallurgyNuclear MaterialsSurface ScienceHigh-temperature MaterialsIon ImplantationMetalsRadiation Damage In MaterialsHelium Bubble FormationImplantation-induced Defect FormationIon Implantation EffectsIon Species DependenceMicrostructureTungsten-based Materials
AbstractThe effect of heating temperature on deuterium (D) retention behavior for helium (He+) / carbon (C+) implanted tungsten (W) was studied. It was found that D retention behavior for He+ implanted W was not limited by the size of the He bubbles. The microstructure observation showed that the large helium bubbles were formed near the surface for He+ implanted W at 1173 K, suggesting that the D retention was reduced by the growth of the helium bubbles. In addition, to evaluate the effect of implantation ion species at high temperature, D retention behavior for He+ implanted W at 1173 K was compared with that for C+ implanted W at 673 K. It is concluded that the D retention depends on ion species, which makes different kinds of damages like He bubbles for He+ implantation and vacancy-ion complex (voids) for C+ implantation.
7
Ick Soo Kim, John Hunn, Naoyuki Hashimoto et al. · Journal of Nuclear Materials · 2000 · 159 citations
Natural Sciences, Materials Engineering, Materials Science +17