Steam explosion experiments at intermediate scale: FITSB series

D.E. Mitchell, N. A. Evans

OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1986 · 18 citations · 0 references

Concepts

Abstract

Experiments in the FITS chamber have been performed in which 18.7 kg of molten iron-alumina core melt simulant was delivered into water chambers in which the water mass was 1.5 to 15 times greater than the melt. Experiments in subcooled water showed that spontaneous explosions occurred over the range of water/melt mass ratio and geometry used and that in certain experiments, double explosions occurred. With double explosions, the first explosion enhanced fuel-coolant mixing for the second explosion. In one test in saturated water, multiple trigger sites were observed but no propagating explosion resulted. Two distinct, but additive, energy conversion ratios were calculated from the test results. Based on pressure records and debris velocities, a kinetic energy conversion ratio, eta/sub KE/, had calculated values between 0.3 and 1.6%. A conversion ratio, eta/sub D/, related to the work done in pressurizing the chamber air ranged between 0.2% and 8.6%. The total fraction of the melt thermal energy converted, eta/sub tot/ = eta/sub KE/ + eta/sub D/, reached a value of 9.9% in an experiment involving a double explosion, but in this case, the value of eta/sub KE/ was limited to 1.3%. 10 refs.