Evaluation of the VentricularSystem in Adults byTranscranial DuplexSonography

G Seidel, Tibo Gerriets, Manfred Kaps, A. Hutzelmann

Journal of Neuroimaging · 1995 · 141 citations · 9 references

Concepts

TL;DR

Transcranial duplex color‑flow sonography provides visualization of intracranial structures and measures angle‑corrected blood flow velocity in the basal cerebral arteries of adults. The study aimed to evaluate the intra‑ and inter‑observer reproducibility of transcranial duplex measurements of ventricular diameters. Using a 2.5‑MHz transducer, the authors measured the oblique diameters of the third and lateral ventricles in patients and healthy volunteers, comparing them to computed tomography and assessing reproducibility. The measurements showed strong correlations with CT (r = 0.83–0.73), excellent inter‑observer reproducibility (r = 0.87–0.90), high intra‑observer reproducibility (r = 0.93), age‑dependent ventricular sizes, and confirmed that transcranial duplex can noninvasively measure third and lateral ventricles in adults.

Abstract

Transcranial duplex color‐flow sonography provides visualization of intracranial structures, and measures angle‐corrected blood flow velocity in the basal cerebral artenes of adults. In 44 patients with central nervous system disease, the oblique diameters of the third and the middle part of the lateral ventricle were measured by transcranial duplex color‐flow sonography using a system with a 2.5‐MHz transducer, and compared to computed tomography measurements. The correlation coefficients for the third and lateral ventncle measurements were r = 0.83 (p < 0.0001, N = 38) and 0.73 (p < 0.0001, N = 78), respectively. A second investigation was performed by transcranial duplex to evaluate intraobserver and mterobserver reproducibility. The correlation coefficient representing interobserver reproducibility in 27 patients was r = 0.87 (p < 0.0001, N = 47) for the lateral ventricle and r = 0.9 (p < 0.0001, N = 49) for the third ventricle. The intraobserver reproducibility correlation coefficient was r = 0.93 (p < 0.0001, N = 22) for the lateral ventricle in 12 patients. In 49 healthy volunteers the oblique diameters of the lateral and third ventricles were age dependent measuring 16.7 ± 2.3 mm and 4.8 ± 1.9 mm, respectively, in those younger than 59 years, compared to 19.0 ± 2.9 mm and 7.6 ± 2.1 mm in those 60 years or older. Therefore, transcranial duplex color‐flow sonography measures noninvasively the third and the lateral ventncle in adults.

References

9