Documented Subacute Stent Thrombosis Within Thirty Days After Stenting With Sirolimus-Eluting Stent (Cypher ) for Acute Myocardial Infarction A Japanese Single Center Retrospective Non-Randomized Study

Tetsuya Ishikawa, Makoto Mutoh, Yuji Fuda, Hiroshi Sakamoto, Hisayuki Okada, Michiaki Higashitani, Y Nakano, Junichi Yamaguchi, Kenji Enta, Takahiro Satoh,

Circulation Journal · 2006 · 18 citations · 9 references

DOIFull text

Open access

Concepts

Abstract

BACKGROUND: The incidence of subacute stent thrombosis (SAT) within 30 days after stenting with a sirolimus-eluting stent (Cypher) for acute myocardial infarction (AMI) was retrospectively compared to that with bare-metal stents (BMS). METHODS AND RESULTS: Among 559 lesions in 558 consecutive AMI from April 2003 to February 2006, the incidence of documented SAT after Cypher implantation (2/276 lesions, 0.72%) was almost the same as for BMS (2 cases, 0.71%). Aspirin (81-100 mg/day) plus ticlopidine (200 mg/day) were administered continuously after admission in all 4 cases. CONCLUSION: Documented SAT did not increase after stenting with Cypher for AMI under aspirin plus ticlopidine.

References

9