Nuclear Science and Engineering · 1986 · 12 citations · 2 references
EngineeringNuclear EngineeringRadiation DosimetryRadiation TransportReactor PhysicsDose Uncertainty AnalysisReactor InstrumentationThermal-hydraulic Safety AnalysisAdjoint FormulationAdjoint Transport EquationDosimetersLeakagePressure Vessel AnalysisRadiation DosimetersRadiation Source CharacterizationSource Dosimetry
A technique is described to account for effects of space- and time-dependent core source variations on pressure vessel surveillance dosimetry analysis. The procedure first defines an easily implemented geometry for a single adjoint transport calculation. The results from the adjoint calculation can then be combined with those from a single forward calculation, in conjunction with an adjoint scaling technique, to yield activities and pressure vessel fluxes simultaneously for a wide range of source distributions, dosimeter response functions, and detector locations. This method has been implemented in the LEPRICON code system for vessel fluence determination. An application to an R-θ model of an operating power reactor shows that effects of source perturbations resulting in 20% changes in the core leakage can be predicted within ∼3% at both downcomer and cavity dosimeter locations, for six different dosimeters, by choice of a single suitable adjoint response function.
2
R.E. Maerker, B.L. Broadhead, J. J. Wagschal · Nuclear Science and Engineering · 1985 · 36 citations