Journal of the American College of Cardiology · 2015 · 81 citations · 21 references
MedicineCardiologyRadiologyBiomedical ImagingClinical CardiologyDiagnostic ImagingCardiac AssessmentCardiac ImagingCardiac PacingCardiovascular ImagingImplantable Cardioverter-defibrillator CareMagnetic Resonance ImagingImplantable Cardioverter DefibrillatorsPacingPacing Threshold TestingPacing ThresholdsPrimary Efficacy EndpointsRandomized Clinical TrialsSafety Endpoint AssessmentWaiting Period Duration
BACKGROUND: Magnetic resonance imaging (MRI) of patients with conventional implantable cardioverter-defibrillators (ICD) is contraindicated. OBJECTIVES: This multicenter, randomized trial evaluated safety and efficacy of a novel ICD system specially designed for full-body MRI without restrictions on heart rate or pacing dependency. The primary safety objective was >90% freedom from MRI-related events composite endpoint within 30 days post-MRI. The primary efficacy endpoints were ventricular pacing capture threshold and ventricular sensing amplitude. METHODS: Subjects received either a single- or dual-chamber ICD. In a 2:1 randomization, subjects either underwent MRI at 1.5-T of the chest, cervical, and head regions to maximize radiofrequency exposure up to 2 W/kg specific absorption rate and gradient field exposure to 200 T/m/s per axis (MRI group, n = 175), or they underwent a 1-h waiting period without MRI (control group, n = 88). A subset of MRI patients underwent ventricular fibrillation induction testing post-MRI to characterize defibrillation function. RESULTS: In 42 centers, 275 patients were enrolled (76% male, age 60.4 ± 13.8 years). The safety endpoint was met with 100% freedom from the composite endpoint (p < 0.0001). Both efficacy endpoints were met with minimal differences in the proportion of MRI and control patients who demonstrated a ≤0.5 V increase in ventricular pacing capture threshold (100% MRI vs. 98.8% control, noninferiority p < 0.0001) or a ≤50% decrease in R-wave amplitude (99.3% MRI vs. 98.8% control, noninferiority p = 0.0001). A total of 34 ventricular tachyarrhythmia/ventricular fibrillation episodes (20 induced; 14 spontaneous) occurred in 24 subjects post-MRI, with no observed effect on sensing, detection, or treatment. CONCLUSIONS: This is the first randomized clinical study of an ICD system designed for full-body MRI at 1.5-T. These data support that the system is safe and the MRI scan does not adversely affect electrical performance or efficacy. (Confirmatory Clinical Trial of the Evera MRI System for Conditionally-Safe MRI Access; NCT02117414).
21
John G.F. Cleland, Andrew J.S. Coats, Ewa A. Jankowska et al. · PubMed · 2021 · 19.5K citations
2013 ACCF/AHA Guideline for the Management of Heart Failure
Clyde W. Yancy, Mariell Jessup, Biykem Bozkurt et al. · Journal of the American College of Cardiology · 2013 · 12.6K citations
John J.V. McMurray, Stamatis Adamopoulos, Stefan D. Anker et al. · European Heart Journal · 2012 · 6.9K citations · Full text
Amiodarone or an Implantable Cardioverter–Defibrillator for Congestive Heart Failure
Gust H. Bardy, Kerry L. Lee, Daniel B. Mark et al. · New England Journal of Medicine · 2005 · 6.5K citations · Full text