Static internal performance of convergent single-expansion-ramp nozzles with various combinations of internal geometric parameters

E. A. Bare, F. J. Capone

NASA STI Repository (National Aeronautics and Space Administration) · 1989 · 11 citations · 0 references

Full text

Open access

Concepts

Abstract

An investigation was conducted in the Static Test Facility of the Langley 16-Foot Transonic Tunnel to determine the effects of five geometric design parameters on the internal performance of convergent single expansion ramp nozzles. The effects of ramp chordal angle, initial ramp angle, flap angle, flap length, and ramp length were determined. All nozzles tested has a nominally constant throat area and aspect ratio. Static pressure distributions along the centerlines of the ramp and flap were also obtained for each configuration. Nozzle pressure ratio was varied up to 10.0 for all configurations.