Night Firing Range Performance following Photorefractive Keratectomy and Laser In Situ Keratomileusis

Kraig S. Bower, J.M. Burka, Prem S. Subramanian, Richard D. Stutzman, Michael J. Mines, Jeff Rabin

Military Medicine · 2006 · 12 citations · 6 references

Concepts

Abstract

OBJECTIVE: To investigate the effect of laser refractive surgery on night weapons firing. METHODS: Firing range performance was measured at baseline and postoperatively following photorefractive keratectomy and laser in situ keratomileusis. Subjects fired the M-16A2 rifle with night vision goggles (NVG) at starlight, and with iron sight (simulated dusk). Scores, before and after surgery, were compared for both conditions. RESULTS: No subject was able to acquire the target using iron sight without correction before surgery. After surgery, the scores without correction (95.9 +/- 4.7) matched the preoperative scores with correction (94.3 +/- 4.0; p = 0.324). Uncorrected NVG scores after surgery (96.4 +/- 3.1) exceeded the corrected scores before surgery (91.4 +/- 10.2), but this trend was not statistically significant (p = 0.063). CONCLUSION: Night weapon firing with both the iron sight and the NVG sight improved after surgery. This study supports the operational benefits of refractive surgery in the military.

References

6