Procedures for the Collection of Representative Water Quality Data from Monitoring Wells

James P. Gibb, Rudolph M. Schuller, Robert A. Griffin

1981 · 49 citations · 7 references

Concepts

Abstract

Data collected from six monitoring wells at waste disposal sites in Illi­ nois were used to evaluate procedures for the collection of representative water samples from monitoring wells. The effects of four types of pumping mechanisms, the extent of well flushing, the rate and time of pumping, and storage and preservation techniques on chemical composition of water samples were studied. Pump tests and multiple sample experiments provided data on which recommended sampling protocols and sample preservation, preparation, and storage procedures are based. The selection of the type of sampling device; sample preparation, preser­ vation and storage; and sampling procedures all must be tailored to the size and accessibility of the individual well, its hydrologic and chemical charac­ ter, the chemical constituents of interest, and the purpose for monitoring the site. Generally recommended sampling procedures include: 1) using peristal­ tic or submersible diaphragm type pumps when possible; 2) conducting pump tests prior to sampling to determine sampling frequency and time and rate of pumping; 3) flushing the well by pumping four to six well volumes; 4) measur­ ing key parameters such as pH, specific conductance, oxidation-reduction po­ tential, and alkalinity at the time of sample collection; and 5) filtering samples immediately on site through a 0.45 μm pore size filter and then pre­ serving the samples immediately after filtration, according to U.S. EPA (1979) recommended procedures.

References

7