Concepedia

Publication | Closed Access

Fault Detection and Diagnosis of 3-Phase Inverter System

16

Citations

5

References

2001

Year

Abstract

Abstract – This paper describes a method of detection and identification of transistor base drive open-circuit fault of 3-phase voltage source inverter (VSI), feeding a fuzzy logic controlled induction motor. The detection mechanism is based on a novel technique of wavelet transform. In this method, the stator currents will be used as an input to the system. No direct access to the induction motor is required. The detection mechanisms have been rigorously examines theoretically and experimentally, and it has been shown that the developed system is robust and reliable. Résumé – Cet article décrit une technique d’identification et de détection d’une panne a la base d’un transistor, qui compose le convertisseur d’une source de tension triphasée, ce dernier alimente un moteur a induction contrôler par une logique flou. Le mécanisme de détection est base sur le principe de la transformée en wavelet (ondelette). Dans cette méthode, le courent issue du stator sert d’entrée au système, ainsi, l’accès au moteur a induction n’est pas nécessaire. Les performances du système développe ont été mises en évidence par une étude théorique et une étude pratique.

References

YearCitations