Scientific Reports · 2026 · 18 citations · 22 references
EngineeringToxicologyAir PollutionBiosensorsSensorsAir Pollution MeasurementCarbon MonoxideChronic Obstructive Pulmonary DiseaseGas SensorsRespiratory MonitoringRespiratory PathophysiologyCarbon Monoxide DetectionCarbon Monoxide SensorsMetal Oxide Gas SensorsSemiconductor Gas SensorsSensor TechnologyWearable Diagnostic DevicesWearable Diagnostic SensorsWearable Gas Sensors
Chronic Obstructive Pulmonary Disease (COPD) is a progressively debilitating and life-threatening respiratory condition that has long been attributed to exposure to airborne toxic substances like carbon monoxide (CO), a reliable biomarker of oxidative stress, especially in smoking individuals. To address the need for a real-time and non-invasive method that can detect this life-threatening condition, a wearable diagnostic device is developed in this work based on a Z/S heterostructure thin-film gas sensor that can detect exhaled CO at a temperature as low as 37 °C. This gas sensor was prepared using a hydrothermal synthesis route and characterized by various techniques like X-ray diffraction (XRD), Field Emission Scanning Electron Microscopy (FESEM), and Energy-dispersive spectroscopy (EDS), and packed in a face mask design that enables continuous sampling of breath. Of all the sensing devices prepared with varying concentrations of the active components ZnO (Z), SnO₂ (S), and the combination of both (Z/S), the Z/S structure showed maximum sensitivity with a sensitivity of 264.29% at 12 parts per million (ppm), a response time of 14 seconds, and a recovery time of 3 seconds. The incorporation of a polymer layer of poly(3,4-ethylenedioxythiophene): poly(styrenesulfonate) (PEDOT: PSS) improved the charge carrier mobility through p-n junction formation. A customized gas sensing laboratory chamber enabled accurate calibrations of CO sensing. To derive actual CO levels from the resistance changes in the sensor, a power-law model was used. To classify patient groups further as current smokers, ex-smokers, and non-smokers accurately, a support vector machine (SVM) classification with a training accuracy of 94.2% and testing accuracy of 81.7% was used in this work. By integrating nanostructured gas sensors with wearable technology design concepts and ML diagnostics in a seamless Internet of Things (IoT) network, this scientific development will allow early diagnosis of the life-threatening condition of COPD in a completely non-invasive and non-destructive fashion with high portability. This developed device has unending possibilities in taking up roles in individualized breath medical care and represents a significant milestone in translating on-body disease detection using sensor technology.
22
Conduction Model of Metal Oxide Gas Sensors
Nicolae Bârsan, Udo Weimar · Journal of Electroceramics · 2001 · 2.6K citations
Natural Sciences, Materials Engineering, Materials Science +14
Zhufeng Wang, Junfeng Lin, Lina Liang et al. · Respiratory Research · 2025 · 110 citations · Full text
Keisuke Yoshida, Naoki Uchida, Yoshiaki Matsumoto et al. · Geophysical Research Letters · 2023 · 78 citations · Full text