Immunofluorescence test for IgM rubella antibodies in whole serum after absorption with anti-gammaFc.

R. Gispen, J. Nagel, B Brand-Saathof, S. de Graaf

PubMed · 1975 · 47 citations · 20 references

Concepts

Abstract

A technique for detecting IgM rubella antibodies by immunofluorescence was developed. Total serum IgG was removed by prior immunoabsorption with anti-gammaFc. This prevents interference by rheumatoid factors in the serum. The test appeared sensitive and specific in sera of rubella convalescents and infants with congenital rubella.

References

20