Purdue e-Pubs (Purdue University System) · 2002 · 26 citations · 1 references
Open access
EngineeringChemical EngineeringMechanical EngineeringHeat TransferCarbon CycleExpansion Chamber DesignExpansion Device AnalysisExpansion Device DesignFluid Expansion DrivePiston-cylinder Geometry
Carbon dioxide is receiving strong consideration as an alternative refrigerant substituting hydroclorofluorocarbons (HCFCs) and chlorofluorocarbons (CFCs) due to its zero ozone depletion potential and negligible global warming potential.The system performance of CO 2 systems, however, is typically poor compared to the current conventional air conditioning systems using HCFC or CFC.One of the most effective ways to achieve parity with CFC and HCFC systems is to replace the expansion valve with an expansion device that minimizes entropy creation and allows for energy recovery during the expansion process.A piston-cylinder type work output expansion device was designed, constructed and tested as part of the study reported here.The device is based on a highly modified small four-cycle, two-piston engine with a displacement of 2 x 13.26 cm 3 that is commercially available.The work out expansion device replaced the expansion valve in an experimental transcritical CO 2 cycle and increased the system performance by up to 10%.
1