1965 · 37 citations · 0 references
EngineeringCivil EngineeringNuclear EngineeringFoundation EngineeringGeotechnical EngineeringSoil MechanicsSoil-structure InteractionTunnelingCohesionless Soil BehaviorGround - Structure InteractionGround-structure InteractionLining Load AnalysisTunnel-soil Interaction
AT SIZEWELL NUCLEAR POWER STATION, EIGHT VERTICAL SHAFTS WERE CONSTRUCTED FROM THE COOLING WATER TUNNELS BY JACKING CYLINDRICAL LININGS VERTICALLY FROM THE TUNNEL TO SEA BED LEVEL. THIS SHAFT RAISING WAS CARRIED OUT IN COHESIONLESS SOIL THROUGH A DEPTH OF ABOUT 20 FEET. THE PROBLEM OF DETERMINING THE REQUIRED JACKING LOADS IS SIMILAR TO THAT OF THE TENSILE LOADS REQUIRED TO PULL OUT PYLON FOUNDATIONS. AS NO SATISFACTORY THEORY EXISTS FOR THE CALCULATION OF THESE LOADS, THE PROBLEM WAS RESOLVED BY THE USE OF MODEL EXPERIMENTS. THE JACKING LOADS REQUIRED IN THE FIELD FELL WITHIN THE RANGE OF THOSE PREDICTED FROM THE MODEL STUDIES. /LCPC/RRL/A/