EngineeringElectrical EngineeringMarine EngineeringElectrochemical EngineeringOffshore EngineeringOffshore StructuresAnode MaterialsCathodic ProtectionCurrent DistributionElectrode MaterialsMarine ProtectionReference ElectrodesAnode DesignCost-effectivenessCurrent DensityDesign CriteriaDesign Of Cathodic Protection SystemsMarine Structure Cathodic ProtectionOffshore Platform ProtectionSilver-silver Chloride Electrode
Abstract The cathodic protection systems of two platforms installed by Conoco Netherlands in the Southern North Sea were based on accepted design criteria. The use of elongated anodes resulted in high initial current densities that polarized the structures well beyond the minimum protective potential. The results of surveys carried out a few months and one year after installation are presented and discussed. An initial platform current density of the order of 30 mA/ft2 (320 mA/m2) polarized the structures to -0.95 V with respect to the silver/silver chloride reference electrode. It is shown that this initially high current density allows for lowering the maintenance current density. Cost effectiveness will be reflected in a markedly reduced anode weight requirement, and added insurance to obviate any need for premature refrofit.
3
Calculation of resistances to ground
H. B. Dwight · Electrical Engineering · 1936 · 111 citations