Composite steel-deck-reinforced concrete systems failing in shear-bond

R. M. Schuster

E-Periodica · 1972 · 11 citations · 0 references

DOIFull text

Open access

Concepts

Abstract

SHEAR-BOND MAY BE CLASSED AS A BRITTLE TYPE OF FAILURE AND IS CHARACTERIZED BY THE FORMATION OF AN APPROXIMATE DIAGONAL CRACK, RESULTING IN END-SLIP AND LOSS OF BOND BETWEEN THE STEEL DECK AND CONCRETE. THE ULTIMATE SHEAR-BOND CAPACITY OF STEEL-DECK-REINFORCED SYSTEMS IS A FUNCTION OF THE COMPRESSIVE STRENGTH OF CONCRETE, THE DEPTH AND WIDTH OF SLAB, THE THICKNESS OF STEEL DECK, THE SHEAR SPAN AND 2 CONSTANTS TO BE EVALUATED FROM EXPERIMENTAL TEST DATA. A PLUS OR MINUS 18% CORRELATION BETWEEN EXPERIMENTAL AND CALCULATED SHEAR-BOND STRESSES EXISTED. /AUTHOR/