PubMed · 2013 · 14 citations · 5 references
DentistryImplant DentistrySurgeryBone AugmentationImplant ProsthodonticsImplant SurgeryImmediate Implant LoadingImplant MaintenanceImplant SurvivalProvisional RestorationsSocket PreservationEsthetic Zone RestorationImmediate Provisional CrownsImmediate Provisional RestorationsImplant ProvisionalizationImplant Survival AnalysisImplant Survival RatesProvisional Screw-retained RestorationsScrew-retained Provisional Restorations
This prospective study evaluates immediately placed and immediately provisionalized implants in the esthetic zone. All implants were TiO2-blasted, fluoride-modified, grade 4 titanium, with a coronal microthread design. Bone grafting and guided bone regeneration (GBR) was performed at all sites, and screw-retained temporary restorations were delivered on the day of surgery. All of the provisional crown(s) were out of occlusal function and remained in place for at least 8 weeks prior to initiation of definitive restorative therapy. Bone maintenance (BM) was considered successful if radiographs demonstrated proximal bone levels even or coronal to the implant platform. Of the 29 implants placed, 25 (86 percent) achieved bone maintenance at least 12 months post-loading with the final restorations. This study was considered successful, with 100 percent implant survival after at least 1 year loading of the final restoration, and 100 percent of patients were satisfied with the esthetics of their implant treatment.
5
Daniel Buser, Sandro A. Halbritter, Chris Hart et al. · Journal of Periodontology · 2008 · 232 citations
Marco Degidi, Diego Nardi, Adriano Piattelli · Clinical Oral Implants Research · 2010 · 43 citations