STRATEGIC RELOCATION OF PLASTIC HINGES IN BRIDGE COLUMNS

Yael D Hose, M. J. N. Priestley, Frieder Seible

1997 · 19 citations · 0 references

Concepts

Abstract

This report describes the design and testing of seven circular bridge columns for the purpose of studying the effects of relocating the plastic hinge away from supporting members such as cap beams and footings. Test results for the first four columns indicated that the relocation of the plastic hinges led to premature failure consisting of both longitudinal reinforcement buckling and shear. The failure was due to the lack of confinement as the diagonal compression struts in the plastic hinge region could no longer rely on rigid supporting members such as the cap beam or footing. The three remaining columns were tested to study the effects of relocating the plastic hinge on the shear capacity of the column. Shear failures were induced at various ductility levels based on the amount of transverse reinforcement used. Data from experiments indicate that the design technique presented in the report was successful in relocating the plastic hinge region away from the joint region.