NASA STI Repository (National Aeronautics and Space Administration) · 1974 · 10 citations · 0 references
Open access
EngineeringAerospace EngineeringAerodynamicsFlight MechanicsFluid DynamicsPressure MeasurementPressure SensorsShock WavesSupersonic AerodynamicsFrequency Response TestingInlet DesignLag PhasePositionShock Wave MeasurementStatic PressureStatic Pressure MeasurementSupersonic Inlets
An electronic sensor was built to measure the position of the terminal shock in a supersonic inlet. The sensor uses several static-pressure taps in the inlet wall. The sensor output is continuously proportional to shock position. When the sensor was installed in a YF-12 aircraft flight inlet during wind tunnel tests, it indicated shock position within + or - 5 percent of the total distance covered by the static-pressure-tap region. The maximum error caused by an angle of attack change of 4 deg was less than 25 percent. In the region of normal inlet operation, the angle of attack error is negligible. Frequency-response tests show the amplitude ratio is constant out to 60 Hz, and decreases to about 50 percent at 100 Hz, with a phase lag of 50 deg.