Effects of CO<sub>3</sub><sup>2–</sup>/bicarbonate, Si, and PO<sub>4</sub><sup>3–</sup> on Arsenic sorption to HFO

Thomas R. Holm

American Water Works Association · 2002 · 102 citations · 38 references

Concepts

Abstract

Groundwaters that have elevated arsenic (As) concentrations sometimes have moderate to high ferrous iron concentrations. Soluble As species readily sorb to hydrous ferric oxide (HFO); therefore, conventional water treatment methods that remove soluble iron (Fe) by oxidizing to HFO also remove As. Commonly occurring solutes, including phosphate (PO 4 3– ), silica (Si), and carbonate (CO 3 2– ), also sorb to HFO, and competition between these substances and As species may interfere with As removal. This study simulated Fe/As removal at the pH values, alkalinities, and concentrations of Si and PO 4 3– typical of central Illinois groundwater. The results suggest that for water with a pH &gt; 7, lowering the pH to 7 can overcome CO 3 2– and Si interferences. Lowering the pH of water containing PO 4 3– improves As removal but not to the degree observed in waters containing CO 3 2– and Si. The Dzombak and Morel surface complexation–diffuse‐layer model fits the sorption data fairly well.

References

38