IRMM-1000a and IRMM-1000b uranium reference materials certified for the production date. Part I: methodology, preparation and target characteristics

Zsolt Varga, Célia Venchiarutti, Adrian Nicholl, Judit Krajkó, Jakopic Rozle, Klaus Mayer, Stephan Richter, Yetunde Aregbe

Journal of Radioanalytical and Nuclear Chemistry · 2015 · 19 citations · 27 references

DOIFull text

Open access

Concepts

Abstract

The paper describes the preparation and production of the reference materials, IRMM-1000a and IRMM-1000b, certified for the production date based on the 230 Th/ 234 U radiochronometer in compliance with ISO Guide 34:2009. The production date of the reference materials corresponds to the last separation of 230 Th from 234 U, i.e. when the initial daughter nuclide content in the material was finally removed. For the preparation low-enriched uranium was used, which was purified using a unique methodology to guarantee high U recovery and Th separation efficiency. The CRM is intended for calibration, quality control, and assessment of method performance in nuclear forensics and safeguards.

References

27