Antibiotic sampling from central venous catheters versus peripheral veins.

Cheryl L. McBeth, Ruth J. McDonald, Margaret Hodge

PubMed · 2004 · 21 citations · 0 references

Concepts

Abstract

This study was developed to determine if there are statistically or clinically significant differences in antibiotic levels of blood samples obtained from a central venous catheter (CVC) versus a peripheral vein. Currently there is limited and contradictory information comparing aminoglycoside levels drawn from a central line used for antibiotic infusions versus a separate peripheral blood draw. In this study antibiotic levels drawn from a central line were compared with levels drawn simultaneously from a peripheral vein. Significant clinical and statistical differences were identified based on the type of central catheter in place.