OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · 1996 · 29 citations · 0 references
EngineeringMechanical EngineeringMechanical DesignPerformance-based DesignStructural DynamicsBolted ConnectionsConnection DesignStructural ConnectionsBolt DesignBolted JointsConfiguration Interaction CoefficientsElastic InteractionFlange Technology
Design bolt loading in a bolted flange connection is difficult to obtain because of elastic interaction. Elastic interaction data is presented for two different pipe flanges, three different gasket styles and two different bolting patterns. An algorithm that compensates for elastic interaction is given. Uniform bolt preload ({+-}2%) is obtained in a single pass bolt-up operation. The algorithm is based on experimentally obtained interaction coefficients.