Journal of the American College of Cardiology · 2025 · 18 citations · 16 references
Public HealthChronic Disease PreventionPreventive MedicineAir PollutionAir Pollution ControlEnvironmental HealthAir FiltrationAir PollutantsAir Pollution EpidemiologyAir QualityParticulate MatterPollution PreventionAir PurifiersBlood PressureEpidemiology Of Air Pollution Health EffectsHealth Effects Of Particulate MatterHepa FiltrationHigh-efficiency Particulate Air (Hepa) FiltersHousehold Air Pollution ReductionLinear Mixed Models
BACKGROUND: Particulate matter (PM) pollution is a leading cause of cardiovascular risk and illness, including elevated blood pressure (BP). OBJECTIVES: The purpose of this study was to test the efficacy of in-home air purifiers to reduce BP for adults living adjacent to highways. METHODS: We conducted a pragmatic randomized crossover trial of the effect of high-efficiency particulate arrestance (HEPA) vs sham filtration on BP. Residences were randomized to start with 1 month of HEPA filtration or 1 month of sham filtration. A 1-month wash out period with no filtration was followed by 1 month of the alternate filtration. Participant questionnaire data and BP were collected 4 times, at the start and end of each filtration period. PM concentrations were measured in a subset of residences. Linear mixed models were used to compare the mean change in BP between the HEPA and sham filtration periods. Models were adjusted for time invariant and time-varying covariates. RESULTS: A total of 154 participants were analyzed. The mean age was 41.1 years, 59.7% were women, 68.2% were non-Hispanic White, and a majority were of higher socioeconomic status. The mean baseline brachial systolic blood pressure (SBP)/diastolic BP was 118.8/76.5 mm Hg. HEPA filtration significantly reduced PM in comparison to both indoor sham and outdoor levels. Participants' SBP at the start of the intervention period moderated the efficacy of the intervention (P = 0.03). Participants who had elevated brachial SBP (≥120 mm Hg) had a significant 2.8-mm Hg mean reduction in SBP after HEPA filtration (P = 0.03) and a 0.2-mm Hg mean increase in SBP after sham filtration (P = 0.85). The net result was a significant 3.0-mm Hg mean difference in favor of HEPA filtration (P = 0.04). There was no significant benefit on diastolic BP or for participants with normal SBP (<120 mm Hg). CONCLUSIONS: concentrations.
16
Zhekang Ying, Xiaohua Xu, Yuntao Bai et al. · Environmental Health Perspectives · 2013 · 227 citations · Full text
Ultrafine Particle Metrics and Research Considerations: Review of the 2015 UFP Workshop
Richard Baldauf, Robert B. Devlin, Peter Gehr et al. · International Journal of Environmental Research and Public Health · 2016 · 139 citations · Full text
Public Health, Environmental Engineering, Environmental Sciences +17