IEEE Transactions on Instrumentation and Measurement · 2025 · 14 citations · 27 references
Natural SciencesElectrical EngineeringPhysicsElectromagneticsElectromagnetismMagnetic MaterialsMagnetic Circuit AnalysisRemanent MagnetizationControl FeedbackElectromagnetic Interference SuppressionLeakage FluxMagnetic NoiseMagnetic Noise ReductionSignal-to-noise RatioSignal-to-noise Ratio EnhancementSignal-to-noise Ratio Improvement
The cylindrical magnetic shield (CMS) with the advantages of easy-process, low-cost and portable-mobility is widely utilized in magnetocardiography (MCG) for recording the weak biomagnetic field of cardiac. The one-side-open structure of CMS leads to excessive flux leakage and uneven-distributed magnetic field, which cause extra degradation of sensitivity and signal noise ratio of MCG test. Therefore, an enhanced magnetic suppression technique for reducing the asymmetric-distributed remanence and magnetic noise inside CMS is proposed in this paper. This method introduces the Fourier series with half-angle component for asymmetric compensation field generation and combines the analytic method to model and weaken coupling effect impact. The feedback control is employed in the compensation system for static and dynamic magnetic interference containment. The asymmetric-distributed remanence <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>y</sub></i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>z</sub></i> is suppressed near zero, and the magnetic noise of <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>y</sub></i> and <italic xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">B<sub>z</sub></i> at 0.01 Hz is restrained from 59.3 to 0.06 pT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> and 92.7 to 0.24 pT/Hz<sup xmlns:mml="http://www.w3.org/1998/Math/MathML" xmlns:xlink="http://www.w3.org/1999/xlink">1/2</sup> with the inhibition rate of 29.95 dB and 25.87 dB respectively. The MCG test with high signal-to-noise ratio is then realized inside the MCS with the asymmetric compensation system.
27
Moving magnetoencephalography towards real-world applications with a wearable system
Elena Boto, Niall Holmes, James Leggett et al. · Nature · 2018 · 1.4K citations · Full text
Sarah Strand, William J. Lutter, Janette F. Strasburger et al. · Journal of the American Heart Association · 2019 · 130 citations · Full text
Precision magnetic field modelling and control for wearable magnetoencephalography
Molly Rea, Niall Holmes, Ryan M. Hill et al. · NeuroImage · 2021 · 119 citations · Full text