Ultrasound detection can promptly identify partial discharge (PD) faults inside power transformer by using fiber-optic Fabry-Perot (F-P) array sensors. This paper presents a new design scheme for a wideband acousto-optic direct-coupled F-P sensor. Indirect-coupled F-P sensors have a narrow, highly sensitive response region, and direct-coupled F-P sensors have a wide band response from 1 to 200 kHz. We constructed a PD database by simulating different PD signals in oil tank. We proposed learnable KAN kernel to replace traditional CNN kernel and introduced KAN as a replacement for the ReLU function. Furthermore, we conducted pattern recognition research with a convolutional depth of only 6 layers. The test accuracy on oil tank dataset reached 98.7% for KAN Convolution + ReLU and 99.5% for KAN Convolution + KAN. The validation accuracy achieved by inputting PD signals measured from a real 220 kV power transformer into the two models was 97.5% and 98.75%, respectively.