Effect of an Intramammary Polyethylene Device on the Concentration of Leukocytes and Immunoglobulins in Milk and on the Leukocyte Response to Escherichia coli Endotoxin and Challenge Exposure with Staphylococcus aureus

Max Paape, W. D. Schultze, A. J. Guidry, W.M. Kortum, B.T. Weinland

American Journal of Veterinary Research · 1981 · 29 citations · 0 references

Concepts

Abstract

SUMMARY A sterilized polyethylene intramammary device ( imd ) was inserted through the papillary duct (teat canal) into a front mammary quarter and a rear mammary quarter of 7 cows. The device was 2 mm in diameter and 115 mm long; it was in the form of a loop of 25 mm diameter in situ. Insertion of the imd caused rapid increases in the concentration of milk somatic cells which stabilized at concentrations 50% higher than the milk somatic cell values for the control quarters. Fractions of milk were collected during machine milking to determine the concentrations of milk somatic cells, immunoglobulins (Ig), and bovine serum albumin ( bsa ). Milk somatic cell counts in the 1st, 2nd, and 20th 10-ml milk fractions and in the primary, stripping, and residual milk fractions for imd -fitted quarters averaged 1.090, 0.429, 0.485, 0.512, 1.781, and 1.763 × 10 6 cells/ml. The counts for control quarters averaged 0.280, 0.203, 0.211, 0.300, 0.481, and 0.800 × 10 6 cells/ml, respectively. Counts for imd -fitted quarters were significantly greater than for control quarters for all fractions except the primary milk fraction. The concentrations of Ig and bsa for imd -fitted quarters tended to be higher for all milk fractions when compared with the values for control quarters, but were significant only for IgG2 and bsa in the residual fractions. There was no difference between imd -fitted and control quarters in milk yield, percentage of butterfat, percentage of protein, or solids-not-fat. Injection of 0.01 μg of endotoxin into all quarters resulted in a greatly intensified leukocytic response for imd -fitted quarters compared with the control quarters. Milk somatic cell counts for imd -fitted quarters increased from 0.8 × 10 6 cells/ml before injection to 4.3 × 10 6 at 10 hours after injection, whereas the counts for control quarters increased from 0.4 × 10 6 cells/ml to 1.8 cells/ml of milk. Experimental challenge exposure of all quarters of 5 cows with 23.8 to 115.0 colony-forming units of Staphylococcus aureus strain 305 resulted in infection in 9 of 10 control quarters and in 5 of 10 imd -fitted quarters. With few exceptions, infection occurred when the concentration of somatic cells in the gland was 7 × 10 5 or less/ml of milk at the time of bacterial challenge exposure and failed to occur when the somatic cell concentration was 8.8 × 10 5 or greater/ml.