Analytical Chemistry · 2025 · 12 citations · 39 references
EngineeringBioengineeringChemistryAnalytical ChemistryBiosensorsSensorsBioanalytical ChemistryElectrochemical BiosensorsElectrochemical DetectionEnzymatic BiosensorsEnzyme-based BiosensorsEnzyme-linked Immunosorbent AssayEnzyme-based SensorsEnzyme-mediated PolymerizationPaper-based Analytical DevicesPaper-based BiosensorsPaper-based Diagnostic DevicesPaper-based Enzymatic BiosensorsPaper-based SensorsSignal Readout Techniques
High Resolution Image Download MS PowerPoint Slide The integration of barcode technology with smartphones on paper-based analytical devices (PADs) presents a promising approach to bridging manual detection with digital interpretation and data storage. However, previous studies of 1D barcode approaches have been limited to providing only a “yes/no” response for analyte detection. Herein, a method of using barcode readout for semiquantitative signal detection on PADs has been achieved through the integration of barcode technology with a distance-based measurement concept on PADs. To demonstrate the feasibility of this concept, a PAD fabrication strategy incorporating barcodes was explored, using the enzymatic reaction between horseradish peroxidase (HRP), 3,3′-diaminobenzidine (DAB), and H 2 O 2 as a model system. The enzyme-catalyzed polymerization of DAB to polyDAB in the presence of hydrogen peroxide results in the appearance of color observable by the naked eye inside a paperfluidic channel, with the color-changed length depending on the H 2 O 2 concentration. At the same time, the barcode pattern displayed as a result of this distance-based color evolution overlaid with a paper-based barcode layer can be read using a smartphone application. Parameters affecting the signal readout performance were studied. The developed device can be used to detect H 2 O 2 concentrations in the range of 0.25 to 10 mM within 90 min with 79.6% of barcode signals correctly readable. Additionally, results from different smartphone models showed a consistent reading performance (78.4–79.6%). Finally, the quantification of glucose levels in artificial urine samples was demonstrated. This developed PAD signaling strategy offers end-users more simplicity and can be used as a standalone device or in conjunction with other digital devices.
39
Simple, distance-based measurement for paper analytical devices
David M. Cate, Wijitar Dungchai, Josephine C. Cunningham et al. · Lab on a Chip · 2013 · 347 citations
Lu Chen, Chunsun Zhang, Da Xing · Sensors and Actuators B Chemical · 2016 · 130 citations